Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Injury ; 55(3): 111378, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38309085

RESUMO

INTRODUCTION: Spinopelvic dissociation (SPD) is a severe injury characterized by a discontinuity between the spine and the bony pelvis consisting of a bilateral longitudinal sacral fracture, most of the times through sacral neuroforamen, and a horizontal fracture, usually through the S1 or S2 body. The introduction of the concept of triangular osteosynthesis has shown to be an advance in the stability of spinopelvic fixation (SPF). However, a controversy exists as to whether the spinal fixation should reach up to L4 and, if so, it should be combined with transiliac-transsacral screws (TTS). OBJECTIVE: The purpose of this study is to compare the biomechanical behavior in the laboratory of four different osteosynthesis constructs for SPD, including spinopelvic fixation of L5 versus L4 and L5; along with or without TTS in both cases. MATERIAL AND METHODS: By means of a formerly described method by the authors, an unstable standardized H-type sacral fracture in twenty synthetic replicas of a male pelvis articulated to the lumbar spine, L1 to sacrum, (Model: 1300, SawbonesTM; Pacific Research Laboratories, Vashon, WA, USA), instrumented with four different techniques, were mechanically tested. We made 4 different constructs in 5 specimen samples for each construct. Groups: Group 1. Instrumentation of the L5-Iliac bones with TTS. Group 2. Instrumentation of the L4-L5-Iliac bones with TTS. Group 3. Instrumentation of L5-Iliac bones without TTS. Group 4: Instrumentation of L4-L5-Iliac bones without TTS. RESULTS AND CONCLUSIONS: According to our results, it can be concluded that in SPD, better stability is obtained when proximal fixation is only up to L5, without including L4 (alternative hypothesis), the addition of transiliac-transsacral fixations is essential.


Assuntos
Fraturas Ósseas , Fraturas da Coluna Vertebral , Masculino , Humanos , Parafusos Ósseos , Ílio/cirurgia , Fraturas Ósseas/cirurgia , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/cirurgia , Sacro/diagnóstico por imagem , Sacro/cirurgia , Sacro/lesões , Fixação Interna de Fraturas/métodos
2.
Sensors (Basel) ; 17(4)2017 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-28353674

RESUMO

Tire characteristics and behavior are of great importance in vehicle dynamics since the forces transmitted in the tire-road contact are the main contributors to global vehicle performance. Several research groups have focused on the study and modeling of tires. Some of the most important factors that need to be known are tread characteristics and pressure distribution in the tire-ground contact patch. In this work, a test bench has been used to adequately determine the aforementioned factors. The measurement principle of the test bench is the frustration of total internal reflection (FTIR) of light. It makes use of a laterally illuminated glass on which the tire leans. An interposed plastic interface between them causes the reflection of light. Finally, a video camera captures the bright image formed through the glass. The brightness level in each pixel of the image is related to existing normal pressure. A study of the parameters that affect the test bench calibration such as type of interface material used, diffuse light, hysteresis, creep and transverse light absorption is performed. Experimental tests are conducted to relate tire inflation pressure and camber angle to the pressure distribution. Furthermore, the test bench is used to detect and evaluate the influence of defects in the tire on the contact pressures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...